Neutron capture cross-section measurements are fundamental in the studyof astrophysical phenomena, such as the slow neutron capture (s-)process of nucleosynthesis operating in red-giant and massive stars.However, neutron capture measurements via the time-of-flight (TOF)technique on key s-process nuclei are often challenging. Difficultiesarise from the limited mass (similar to mg) available and the highsample-related background in the case of the unstable s-processbranching points. Measurements on neutron magic nuclei, that act ass-process bottlenecks, are affected by low (n,gamma) cross sections anda dominant neutron scattering background. Overcoming these experimentalchallenges requires the combination of facilities with highinstantaneous flux, such as n\_TOF-EAR2, with detection systems with anenhanced detection sensitivity and high counting rate capabilities. Thiscontribution reviews some of the latest detector developments indetection systems for (n,gamma) measurements at n\_TOF, such as i-TED,an innovative detection system which exploits the Compton imagingtechnique to reduce the dominant neutron scattering background ands-TED, a highly segmented total energy detector intended for high fluxfacilities. The discussion will be illustrated with results of the firstmeasurement of key the s-process branching-point reactionSe-79(n,gamma).
New detection systems for an enhanced sensitivity in key stellar (n,γ) measurements
Musumarra AMembro del Collaboration Group
;
2023-01-01
Abstract
Neutron capture cross-section measurements are fundamental in the studyof astrophysical phenomena, such as the slow neutron capture (s-)process of nucleosynthesis operating in red-giant and massive stars.However, neutron capture measurements via the time-of-flight (TOF)technique on key s-process nuclei are often challenging. Difficultiesarise from the limited mass (similar to mg) available and the highsample-related background in the case of the unstable s-processbranching points. Measurements on neutron magic nuclei, that act ass-process bottlenecks, are affected by low (n,gamma) cross sections anda dominant neutron scattering background. Overcoming these experimentalchallenges requires the combination of facilities with highinstantaneous flux, such as n\_TOF-EAR2, with detection systems with anenhanced detection sensitivity and high counting rate capabilities. Thiscontribution reviews some of the latest detector developments indetection systems for (n,gamma) measurements at n\_TOF, such as i-TED,an innovative detection system which exploits the Compton imagingtechnique to reduce the dominant neutron scattering background ands-TED, a highly segmented total energy detector intended for high fluxfacilities. The discussion will be illustrated with results of the firstmeasurement of key the s-process branching-point reactionSe-79(n,gamma).| File | Dimensione | Formato | |
|---|---|---|---|
|
Musumarra_New-detection-systems.pdf
accesso aperto
Tipologia:
Versione Editoriale (PDF)
Licenza:
Creative commons
Dimensione
2.64 MB
Formato
Adobe PDF
|
2.64 MB | Adobe PDF | Visualizza/Apri |
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.